Industrial steam generators

Static Steam Generators

Steam generator NGV 60

Fixed steam generator with 6 available configurations. Offers variable power from 20 to 60 kW, with a 60-liter boiler and steam production of up to 80 kg/h.

Steam generator NGV 60 NGV6060 Correct size. Giconmes industrial steam generators
Steam generator NGV 60 NGV6060 Correct size. Giconmes industrial steam generators
NGV6060

Features NGV 60

The NGV60 is our most sought-after fixed generator by our clients. It can be configured with 6 different power options, and the boiler has a capacity of 60 liters. It can be manufactured in AISI 304 or AISI 316 stainless steel (suitable for the food industry). It is capable of producing up to 80 kg/h of saturated steam at a maximum pressure of 8.5 bar. It has multiple applications, but it is primarily used in industrial processes where heat transfer is required.

Steam generator NGV 60 settings 2. Giconmes industrial steam generatorsGenerates saturated steam within a temperature range of 140º to 180º C

Steam generator NGV 60 link 2. Giconmes industrial steam generatorsSteam pressure range from 0.3 to 8.5 bar.

Steam generator NGV 60 layout list. Giconmes industrial steam generatorsAvailable in 6 configurations according to power needs, ranging from 20 kW to 60 kW.

Steam generator NGV 60 sliders. Giconmes industrial steam generatorsA 60-liter capacity boiler.

Steam generator NGV 60 timer. Giconmes industrial steam generatorsHigh versatility, it is used in sterilization processes, autoclave feeding, mushroom cultivation, beer production, and various industrial heating processes.

ModelNGV 6020NGV 6024NGV 6030NGV 6040NGV 6048NGV 6060
Power of the heating elements (kW)20kW (x1)24kW (x1)30kW (x1)20kW (x2)24kW (x2)30kW (x2)
Total power (kW)202430404860
Total power (kcal/h)17.20020.64025.80034.40041.28051.600
Steam production (kg/h)273240536480
Number of boilers111111
Boiler capacity (L)60 L60 L60 L60 L60 L60 L

Why choose an electric steam generator?

  • Quick startup. Steam can be obtained in 5 minutes.
  • Can be fed from the water network or from a stainless steel tank.
  • Safety and efficiency thanks to triple boiler insulation.
  • Can be conveniently located near the application area.
  • No installation project or boiler room is required.
  • The power source can be from sustainable origins.

Steam generator accessories

Custom-designed accessories for each customer.
Optimize operating costs, steam quality, and find solutions to your needs by incorporating the available accessories to your generator. We will be delighted to assist you in selecting the right ones for your requirements!

Industries and Applications for the NGV 60

Steam is used in heating, sterilization, or sanitation processes.
The engineers at Giconmes have been developing numerous applications based on heat transfer through steam since 1957. You can find examples of our solutions in the following case studies

Conveyor Cleaning IMG 3346 scaled. Giconmes industrial steam generators

Vapor-based Conveyor Cleaning System in a Food Company

Flecha

Steam generator NGV 60 dot. Giconmes industrial steam generatorsFAQs

We understand that many questions may arise. Here are some of the most common ones

There are no emissions other than those produced in the electricity production process. Therefore, they can be neutral depending on the electricity mix Electric steam boilers are indeed the present and the future

Absolutely. It is even recommended for achieving maximum efficiency. There is no problem with remote control as long as current regulations are followed.

A steam generator is a pressure vessel that, along with the connected pipe network, is subject to regulatory control and complementary technical instructions, as stated in the regulations published in Royal Decree 809/2021, dated September 21st. The maintenance of an electric steam generator is divided into a part that can be easily carried out by the owner:

  1. Familiarize yourself with and apply the manufacturer’s instructions regarding the use, safety measures, and maintenance.
  2. Do not put the installation into service or prevent the operation of pressure equipment if they do not meet the requirements of the regulations.
  3. Maintain at least the following documentation of the pressure equipment while they are installed: Declaration of Conformity, if applicable, manufacturer’s instructions, and, if necessary, installation certificate, along with other supporting documentation (such as Installation Project, record of the last periodic inspection, certifications of equipment repairs or modifications, as well as any other documentation required by the corresponding complementary technical instruction (ITC) of this regulation). For detailed information, please refer to Annex IV of the regulation. This documentation must be made available to the competent authority of the autonomous community and to the companies responsible for maintenance, repair, or periodic inspections.
  4. Use pressure equipment within the operating limits specified by the manufacturer, and withdraw them from service if they no longer meet the necessary safety requirements.
  5. Perform maintenance on the installations, pressure equipment, safety accessories, and control devices in accordance with the operating conditions and manufacturer’s instructions, and examine them at least once a year.
  6. Arrange for the necessary periodic inspections as stipulated in Article 6 of the regulation.
  7. Maintain an up-to-date record of pressure equipment belonging to categories I to IV, as defined in RD 709/2015, dated July 24th, or equipment deemed equivalent to these categories according to Article 3.2 of the regulation, as well as their installations.

It is known that by applying heat to water, it transforms into steam at its boiling point under atmospheric pressure. From there, depending on the desired level of steam saturation for its proper application, we may need to increase the pressure in order to achieve higher temperature. To change the temperature and saturation level of steam, it is indeed necessary to modify the pressure.

It is a unit of pressure equivalent to 1 kg/cm2, 0.98 atmospheres, or 14.50 PSI.

Haven't found the answers to your questions?

Please send us a question or download all the information

    Steam generator NGV 60 CTA 2. Giconmes industrial steam generators

    Quick technical service, with trained professionals and service plans focused on your company

    What kind of steam system do you need?

    Equipment rental

    Reliable, safe equipment with a 5-year warranty.

    Enjoy the security of a personalized service
    24/7 adapted to your needs.

    EQUIPMENT RENTAL

    Steam generator NGV 60 alquiler maquinaria. Giconmes industrial steam generators
    Steam generator NGV 60 CTA 3. Giconmes industrial steam generators

    Do you need a customized solution?

    We help you define what type of installation you need

    Steam generator NGV 60 LINE blog. Giconmes industrial steam generators

    Giconmes technology blog

    Here you will find informative articles about steam technology, its application in industry, and different types of related equipment, as well as the latest trends, installations we have created and new developments in boilers or steam generators for the entire industry.

    GO TO THE BLOG