Industrial steam generators

Static Steam Generators

HGV range
and HGV-W

Large capacity steam and hot water boilers (up to 10 MW in steam and 30 MW in hot water). Complete systems including feed tank, purge systems, electrical cabinet and control panel all mounted on a SKID.

HGV range <br>and HGV-W 23 0081 00 1. Giconmes industrial steam generators
HGV range <br>and HGV-W 23 0081 00 3 e1712316605869 edited 1. Giconmes industrial steam generators

HGV range

Steam Boilers

Converting electrical energy into heat is becoming increasingly common. Thanks to the increase in renewable energy installations, there are times of the day when surplus electricity is produced at a very low cost. This surplus can be converted into thermal energy with so-called “PowertoHeat” systems.

The HGV range of boilers specially manufactured for heat transfer can produce up to 10,000kg/hour of steam at 16 bar.

HGV range <br>and HGV-W settings 2. Giconmes industrial steam generatorsPlug and play: mounted on SKIDS for easy on-site installation

HGV range <br>and HGV-W link 2. Giconmes industrial steam generatorsElectric operation does not require gas/oil supply or chimney system

HGV range <br>and HGV-W layout list. Giconmes industrial steam generatorsUp to 10MW and 15 bar
Low and medium voltage

HGV range <br>and HGV-W sliders. Giconmes industrial steam generatorsControl panel with system visualization, various interfaces to existing building management systems (BMS)

HGV range <br>and HGV-W timer. Giconmes industrial steam generatorsDesign and manufacture according to PED 2014/68/EC or ASME Sect. VIII Div. 1

Elements included in a high-capacity clean steam system

HGV range <br>and HGV-W Number 1. Giconmes industrial steam generators

Clean steam generator

Clean steam boiler made of high quality stainless steel AISI 316.

HGV range <br>and HGV-W Number 2. Giconmes industrial steam generators

Purge system

Washing of the bottom of the boiler where sediments accumulate.

HGV range <br>and HGV-W Number 3. Giconmes industrial steam generators

Level control

Through water conductivity. If the value is too high, the valve opens until the measured value drops below the set point.

HGV range <br>and HGV-W Number 4. Giconmes industrial steam generators

Pressure control

The pressure will be adjusted mechanically (by means of a mechanical pressure control valve) or electrically by means of a pressure transmitter (control panel) and an electrically operated valve.

HGV range <br>and HGV-W Number 5. Giconmes industrial steam generators

Steam supply

Clean steam output from the steam generator.

HGV range <br>and HGV-W Number 6. Giconmes industrial steam generators

500 liter fermenter

Accumulation of boiler feed water. It also serves as a condensate collector. Includes water preheating system

HGV range <br>and HGV-W Number 7. Giconmes industrial steam generators

System for draining excess water in the reservoir

HGV range <br>and HGV-W Number 8. Giconmes industrial steam generators

Heating flange for electric heating elements

HGV range <br>and HGV-W Number 9. Giconmes industrial steam generators

Cooling system

HGV range <br>and HGV-W Number 10 1. Giconmes industrial steam generators

Levelcontrol

A water level control system is required. Low and high water protection is installed.

HGV range <br>and HGV-W esquema sistemas de vapor limpio de alta capacidad. Giconmes industrial steam generators
HGV range <br>and HGV-W Number 11. Giconmes industrial steam generators

Water preheating

To protect the boiler against large temperature differences and thermal stresses, the feed water must be preheated by steam injection.

HGV range <br>and HGV-W Number 12. Giconmes industrial steam generators

Drainage

To empty the tank.

HGV range <br>and HGV-W Number 13. Giconmes industrial steam generators

Water supply connection

To feed water pumps and boilers.

HGV range <br>and HGV-W Number 14. Giconmes industrial steam generators

Return condensing

It collects condensate from different elements, e.g. steam pipe drain points or heat exchangers.

HGV range <br>and HGV-W Number 15. Giconmes industrial steam generators

Blow cooler

To cool the hot water of the purges.

HGV range <br>and HGV-W Number 16. Giconmes industrial steam generators

Water sample cooler

For daily analysis of boiler water.

HGV range <br>and HGV-W Number 17. Giconmes industrial steam generators

Feed water pump unit

Vertical multistage centrifugal feedwater pump feeding the steam generator. The pump is designed according to the maximum steam pressure and flow capacity of the steam boiler.

HGV range <br>and HGV-W Number 18. Giconmes industrial steam generators

Main control panel

With independent regulation of steam generation and control of safety devices.

HGV range

Model No.Capacity
kg/h
Power rating
kW @ 10bar
Operating pressure
bar(g)
Approximate dimensions
(in mm)
Mains voltage / Frequency
HGV-2502501406/10/163200 x 1500 x 20003 PH 400V/690V – 50Hz/60Hz
HGV-5005002806/10/163750 x 1500x 23003 PH 400V/690V – 50Hz/60Hz
HGV-7507504206/10/164200 x 1500 x 25003 PH 400V/690V – 50Hz/60Hz
HGV-100010005606/10/164500 x 1500 x 26003 PH 400V/690V – 50Hz/60Hz
HGV-150015008356/10/165000 x 1750 x 32003 PH 400V/690V – 50Hz/60Hz
HGV-2000200011206/10/165500 x 1750 x 35003 PH 400V/690V – 50Hz/60Hz
HGV-2500250013956/10/166000 x 2000 x 38003 PH 400V/690V – 50Hz/60Hz
HGV-3000300016706/10/16on request3 PH 400V/690V – 50Hz/60Hz
HGV-4000400022406/10/16on request3 PH 400V/690V – 50Hz/60Hz
HGV-5000500027906/10/16on request3 PH 400V/690V – 50Hz/60Hz
HGV-6000600033406/10/16on request3 PH 690V – 50Hz/60Hz
HGV-7500750044806/10/16on request3 PH 690V – 50Hz/60Hz
HGV-100001000055806/10/16on request3 PH 690V – 50Hz/60Hz
HGV range <br>and HGV-W agua caliente. Giconmes industrial steam generators

HGV – W Range

Hot Water

Hot water generation by means of electric heating elements. The desired hot water temperature is controlled by a microprocessor.

HGV range <br>and HGV-W settings 2. Giconmes industrial steam generatorsHot water generation by means of electric heating elements. The desired hot water temperature is controlled by a microprocessor.

HGV range <br>and HGV-W link 2. Giconmes industrial steam generatorsManufactured with electrical resistors

HGV range <br>and HGV-W layout list. Giconmes industrial steam generatorsUp to 30MW

HGV range <br>and HGV-W sliders. Giconmes industrial steam generatorsDigital control panel with display that integrates into building management systems (BMS)

HGV range <br>and HGV-W timer. Giconmes industrial steam generatorsSuitable for heating, district heating and domestic hot water production

HGV – W Range

Model No.Capacity
liters
Power rating
kW
Water flow rate
(m3/h) Delta T = 20 K
Approximate dimensions
(in mm)
Mains voltage / Frequency
HGV W-75215723,091400 x 1000 x 18003 PH 400V/690V – 50Hz/60Hz
HGV W-1003501084,641400 x 1000 x 18003 PH 400V/690V – 50Hz/60Hz
HGV W-1605001626,9651400 x 1000 x 18003 PH 400V/690V – 50Hz/60Hz
HGV W-25080025210,831750 x 1100 x 22003 PH 400V/690V – 50Hz/60Hz
HGV W-30080030613,161790 x 1100 x 20003 PH 400V/690V – 50Hz/60Hz
HGV W-400125039617,031900 x 1300 x 22003 PH 400V/690V – 50Hz/60Hz
HGV W-500125050421,672820 x 1700 x 22503 PH 400V/690V – 50Hz/60Hz
HGV W-660125066628,632820 x 1700 x 22503 PH 400V/690V – 50Hz/60Hz
HGV W-800125079234,052820 x 1700 x 22503 PH 400V/690V – 50Hz/60Hz
HGV W-10002500100842,992820 x 2350 x 22003 PH 400V/690V – 50Hz/60Hz
HGV W-12003000118851,072820 x 2350 x 23503 PH 400V/690V – 50Hz/60Hz
HGV W-15003500151265,002820 x 2450 x 24503 PH 400V/690V – 50Hz/60Hz
HGV W-20004400201685,984000 x 2500 x 25003 PH 400V/690V – 50Hz/60Hz

Why choose an electric steam generator?

  • Efficiency: Even at low utilization levels, the electric alternative is more efficient than fossil fuels, allowing to reduce the installation size for the same generation capacity.
  • Zero emissions of pollutants: It has neutral direct emissions and the potential to be 100% clean through the use of renewable energy.
  • Safety: There is no combustion, smoke, or other gas emissions. It also does not require a specialist to operate or a boiler room.
  • Maintenance cost:Due to their simpler structural and mechanical design, electric steam generators streamline and reduce maintenance time and costs.
  • Incremental power based on
    needs (modularity):
    The possibility to configure a generator modularly with multiple independent power options.
  • Simplified installation:Electric boilers can be installed near the point of
    steam application, reducing installation costs and inefficiencies in pressure and temperature.

Steam generator accessories

Custom-designed accessories for each customer
Optimize operating costs, steam quality, and find solutions to your needs by incorporating the available accessories to your generator. We will be delighted to assist you in selecting the right ones for your requirements!

Industries and applications for the HGV and HGV-W Range

Steam is used in heating, sterilization, or sanitation processes
The engineers at Giconmes have been developing numerous applications based on heat transfer through steam since 1957. You can find examples of our solutions in the following case studies

Industrial Steam for Assembly UOMJ8165. Giconmes industrial steam generators

Line Steam Installation for Shoe Production

Flecha

HGV range <br>and HGV-W dot. Giconmes industrial steam generatorsFAQs

We understand that many questions may arise. Here are some of the most common ones.

There are no emissions beyond those produced during the electricity production process. Consequently, emissions can be neutral depending on the electricity mix. Electric steam boilers are the present and the future.

Absolutely. In fact, it is recommended to achieve maximum efficiency. There is no problem with remote control as long as it complies with current regulations.

A steam generator is a pressure vessel that, together with the piping network, is subject to regulatory control and complementary technical instructions, according to the regulations published in Royal Decree 809/2021, of September 21. Maintenance is divided into a part that can be easily fulfilled by the owner:

  1. Know and apply the manufacturer’s instructions regarding use, safety measures, and maintenance.
  2. Not to put the installation into service or prevent the operation of pressure equipment if the requirements of the Regulation are not met.
  3. Having at least the following documentation for the pressure equipment while they are installed: Declaration of conformity, manufacturer’s instructions (if applicable), and, if necessary, installation certificate, along with other supporting documentation (such as installation project, record of the last periodic inspection, certifications of equipment repairs or modifications, and any other documentation required by the relevant technical instruction complementary to this regulation). For detailed contents, refer to Annex IV of the regulation. Making this documentation available to the competent authority of the autonomous community and the companies responsible for maintenance, repair, or periodic inspections.
  4. Use the pressure equipment within its intended operating limits as specified by the manufacturer and take it out of service if it no longer meets the necessary safety requirements.
  5. Perform maintenance on the installations, pressure equipment, safety accessories, and control devices in accordance with the operating conditions and manufacturer’s instructions, and examine them at least once a year.
  6. Arranging for the necessary periodic inspections as required by Article 6 of the regulation.
  7. Having and maintaining an up-to-date record of pressure equipment categories I to IV, as defined in RD 709/2015, of July 24, or equipment similar to these categories according to Article 3.2 of the regulation, as well as their installations.

It is known that by applying heat to water, it transforms into steam at the boiling point and atmospheric pressure. From there, depending on the required saturation degree of steam for its proper application, we need to increase the pressure to obtain a higher temperature. To change the temperature and saturation degree of steam, we always need to modify the pressure.

It is a unit of pressure equivalent to 1 kg/cm2, 0.98 atmospheres, or 14.50 PSI.

Haven't found the answers to your questions?

Please send us a question or download all the information

    HGV range <br>and HGV-W CTA 2. Giconmes industrial steam generators

    Quick technical service, with trained professionals and service plans focused on your company

    What kind of steam system do you need?

    Equipment rental

    Reliable, safe equipment with a 5-year warranty.

    Enjoy the security of a personalized service
    24/7 adapted to your needs.

    EQUIPMENT RENTAL

    HGV range <br>and HGV-W alquiler maquinaria. Giconmes industrial steam generators
    HGV range <br>and HGV-W CTA 3. Giconmes industrial steam generators

    Do you need a customized solution?

    We help you define what type of installation you need

    HGV range <br>and HGV-W LINE blog. Giconmes industrial steam generators

    Steam and
    Giconmes

    Here you will find informative articles about steam technology, its application in industry, and different types of related equipment, as well as the latest trends and developments in this field.

    GO TO THE BLOG