Industrial steam generators

How to Replace a Gas Boiler with an Electric One Without Compromising Production

Success stories

How to Replace a Gas Boiler with an Electric One Without Compromising Production

Project Description

A gelatin manufacturer needed to replace the steam generated by gas to sterilize the product, requiring 500 kg/h of clean steam at 8 bar, with a capacity expandable to 750 kg/h, while maintaining a continuous supply through a modular, integrated, and relocatable solution.

CAN WE HELP YOU?

Scroll

Original Situation

What challenges did the client present us with?

Our client, a leading gelatin manufacturer, was in the midst of a project to decarbonize its plant. One of the goals was to stop using gas to generate steam for one of its most critical processes: gelatin sterilization. In this process, steam is injected directly into the product and, in a matter of seconds, heats it to about 140 °C before cooling it down again.

This application dictated the entire design of the facility:

  • Clean steam. The steam comes into direct contact with the gelatin, so it had to be generated in stainless steel equipment using feed water from a reverse osmosis system.
  • Flow rate and pressure. The process requires 500 kg/h of saturated steam at 8 bar, and the customer also wanted to evaluate a capacity of 750 kg/h.
  • Continuity of supply. If steam is interrupted, the line stops. After phasing out the gas-fired boiler, the customer did not want production to become dependent on a single piece of equipment.
  • Space and location. The available area was narrow, and the final location had not yet been decided: the former boiler room might end up being used as production space.
  • Integration and Timeline. The team had to communicate its status to the plant’s PLC and deliver the system as soon as possible.

The engineering firm in charge of the project asked us for an electric clean-steam boiler. The underlying question, however, was this: how to electrify the steam without compromising the reliability of the supply.

Solution Provided

Steam solution developed ad hoc by Giconmes

Proposed Solution

Instead of a single large boiler, we proposed a modular system: three NGV-60180 electric steam generators in a 2+1 configuration. Two units cover the process demand, and the third remains on standby, ready to come online if any of the others shut down.

  • Three NGV-60180 generators. Each provides 180 kW and up to 250 kg/h of steam. With two units running, the process’s required 500 kg/h is achieved; with all three, the system reaches 750 kg/h and 540 kW.
  • Nine independent boilers. Each NGV-60180 incorporates three 60-kW boilers, each with two sets of heating elements. Power is connected in stages and adjusted to actual steam consumption.
  • Stainless steel construction. All components in contact with water and steam are made of AISI A-304, allowing steam to be injected directly into the product.
  • Automatic blowdown. Each generator incorporates a timed blowdown system with a 90-liter stainless steel blowdown tank, which prevents scaling and maintains consistent steam quality.
  • Three independent skids. Each generator was supplied pre-assembled on its own AISI A-304 stainless steel skid, complete with an insulated feed and condensate recovery tank. The customer simply had to connect the skids to its existing steam network.
  • Integration with the plant PLC. A junction box for each generator collects the start-up, water load, minimum level, and overpressure signals from each boiler, as well as the steam supply signal and the low-water signal from the tank.
  • Turnkey project. Engineering, P&IDs, supply, transportation, installation, commissioning, and regulatory approval of the facility were all carried out entirely by Giconmes.

Technology used:

  • NGV-60180 electric steam generators, three units in a 2 + 1 configuration, 180 kW and up to 250 kg/h per unit, 500 kg/h with two units, and 750 kg/h and 540 kW with all three units
  • Nine independent boilers, three per NGV-60180 generator, rated at 60 kW, with two heating element groups per boiler
  • Automatic generator-powered blowdown, with a timed blowdown system and a 90-liter stainless steel blowdown tank
  • Three independent AISI A-304 stainless steel skids, one per generator, with an insulated feed tank and condensate recovery tank
  • Generator junction box for signals indicating operation, water fill, minimum level, overpressure, steam supply, and low water level in the tank

CHALLENGES

We meet our clients’ requirements

How to Replace a Gas Boiler with an Electric One Without Compromising Production generacion vapor. Giconmes industrial steam generators

Reliability of supply. This was the benefit the customer valued most. If one unit shuts down, the backup unit kicks in and the line continues to receive its 500 kg/h of steam.

How to Replace a Gas Boiler with an Electric One Without Compromising Production presion. Giconmes industrial steam generators

Maintenance without interrupting production. Flushing, checks, and inspections are performed on a unit-by-unit basis, while the other two units remain in operation. The standby unit itself serves as a backup, so a spare parts kit was not necessary.

How to Replace a Gas Boiler with an Electric One Without Compromising Production sliders. Giconmes industrial steam generators

Combustion-free steam. The process no longer relies on gas: no burner, no chimney, and no direct emissions at the plant, with an efficiency of nearly 99%.

How to Replace a Gas Boiler with an Electric One Without Compromising Production water. Giconmes industrial steam generators

Power adjusted to demand. The nine boilers are activated in stages, so that the system consumes only what the process requires at any given moment. With all three units running, 750 kg/h is available to meet peak demand or accommodate future growth, without the need for additional investment.

How to Replace a Gas Boiler with an Electric One Without Compromising Production cero emisiones. Giconmes industrial steam generators

Clean, consistent steam. The stainless steel construction and automatic venting system ensure the quality of the steam that comes into contact with the gelatin.

How to Replace a Gas Boiler with an Electric One Without Compromising Production eficiencia. Giconmes industrial steam generators

Quick and relocatable installation. The skids arrive pre-assembled, fit into a small space, and can be moved if the plant reorganizes its rooms. It took less than three months from order to delivery.

How to Replace a Gas Boiler with an Electric One Without Compromising Production CTA 3. Giconmes industrial steam generators

Do you need a customized solution?

We help you define what type of installation you need

There are no emissions beyond those produced during the electricity production process. Consequently, emissions can be neutral depending on the electricity mix. Electric steam boilers are the present and the future.

Absolutely. In fact, it is recommended to achieve maximum efficiency. There is no problem with remote control as long as it complies with current regulations.

A steam generator is a pressure vessel that, together with the piping network, is subject to regulatory control and complementary technical instructions, according to the regulations published in Royal Decree 809/2021, of September 21. Maintenance is divided into a part that can be easily fulfilled by the owner:

  1. Understand and follow the manufacturer’s instructions regarding use, safety measures, and maintenance.
  2. Do not put the installation into service or allow pressure equipment to operate if the requirements of the Regulation are not met.
  3. Having at least the following documentation for the pressure equipment while they are installed: Declaration of conformity, manufacturer’s instructions (if applicable), and, if necessary, installation certificate, along with other supporting documentation (such as installation project, record of the last periodic inspection, certifications of equipment repairs or modifications, and any other documentation required by the relevant technical instruction complementary to this regulation). For detailed contents, refer to Annex IV of the regulation. Making this documentation available to the competent authority of the autonomous community and the companies responsible for maintenance, repair, or periodic inspections.
  4. Use pressure equipment within the operating limits specified by the manufacturer and take it out of service if it no longer meets the necessary safety requirements.
  5. Maintain facilities, pressure equipment, safety accessories, and control devices in accordance with operating conditions and the manufacturer’s instructions, and inspect them at least once a year.
  6. Arrange for the corresponding periodic inspections to be carried out in accordance with the provisions of Article 6 of the regulation.
  7. Having and maintaining an up-to-date record of pressure equipment categories I to IV, as defined in RD 709/2015, of July 24, or equipment similar to these categories according to Article 3.2 of the regulation, as well as their installations.

It is known that by applying heat to water, it transforms into steam at the boiling point and atmospheric pressure. From there, depending on the required saturation degree of steam for its proper application, we need to increase the pressure to obtain a higher temperature. To change the temperature and saturation degree of steam, we always need to modify the pressure.

It is a unit of pressure equivalent to 1 kg/cm2, 0.98 atmospheres, or 14.50 PSI.

Haven't found the answers to your questions?

Send us a question or download all the information

    USES OF STEAM IN INDUSTRY AND OTHER BUSINESSES

    Other similar success stories involving the use of steam

    How to Replace a Gas Boiler with an Electric One Without Compromising Production LINE. Giconmes industrial steam generators

    The use of steam is gaining popularity in various industries due to its effectiveness and environmental benefits.

    In our “Success Stories” section, you can learn more about companies that have adopted this technology and achieved successful results in terms of efficiency and sustainability. Click on the success stories to learn more.

    Generador de vapor eléctrico para máquinas de lavado de IBC 4. Giconmes industrial steam generators

    Situación original ¿Qué retos nos planteó el cliente? El reto: integrar vapor en una máquina de lavado de IBC Nuestro cliente es un fabricante internacional de envases industriales que diseña también su propia maquinaria. Necesitaba incorporar un generador de vapor a uno de sus modelos de máquina para la limpieza de contenedores IBC y bidones. […]

    Flecha
    Skid de vapor sobrecalentado en inox para una envasadora

    Situación original ¿Qué retos nos planteó el cliente? Un fabricante europeo de referencia en maquinaria de envasado industrial, con el que Giconmes ya había desarrollado un skid de vapor limpio sobrecalentado para una línea de termoformado destinada al envasado de queso fundido, volvió a contactar con nosotros ante un nuevo proyecto. En esta ocasión, la […]

    Flecha