Industrial steam generators

Isotank Cleaning SACIVA. Giconmes industrial steam generators

Success stories

Isotank Cleaning

Isotank Heating System

The isotank heating system provides an innovative and effective solution to maintain the proper temperature of products during their transportation and storage in isotanks, ensuring their quality and safety.

NEED ASSISTANCE?

Scroll

Original situation:

Challenges posed by Globaltalke

Globaltalke challenged us to develop a heating system for isotanks that would be safe, efficient, and user-friendly.

  • Receiving imported isotanks with chemicals at a temperature of 25°C that needed to be heated prior to supply.
  • Dependence on an external heating base to which the isotank had to be transported for the operation.
  • All the operational complications involved in terms of coordinating the delivery to the customer.
  • ISO Tank with maleic anhydride: 25,000 L
  • External temperature: 25°C
  • Supply temperature: 75°C
  • Total operation time: 12 hours

Proposed solution:

Customized steam solution developed by Giconmes.

Proposed solution:

§After performing the necessary calculations, we concluded that to achieve a maximum time goal of 12 hours a continuous working 180 kW generator is required.

§The heating operation is managed through an integrated programmable logic controller (PLC) in the generator.

Technology used:

  • Generator: NGV-60180 - 3x2x30 kW INOX AISI 316
  • Power: 3 modules with double resistance (30 kW + 30 kW)
  • Maximum steam production: 243 / 249 kg/hour
  • Condensate recovery.
  • Temperature and time control module.
Isotank Cleaning CTA 3. Giconmes industrial steam generators

Do you need a customized solution?

We help you define what type of installation you need

Isotank Cleaning dot. Giconmes industrial steam generatorsFAQs

We understand that many questions may arise. Here are some of the most common ones.

There are no emissions other than those produced in the electricity production process. Therefore, they can be neutral depending on the electricity mix. Electric steam boilers are the present and the future.

Absolutely. In fact, it is recommended to achieve maximum efficiency. There is no problem with remote control as long as current regulations are followed.

A steam generator is a pressure vessel that, along with the pipe network it is connected to, is subject to regulatory control and complementary technical instructions, according to the regulations published in Royal Decree 809/2021, dated September 21st. Its maintenance is divided into a part that can be easily performed by the owner:

  1. Familiarize yourself with and apply the manufacturer’s instructions regarding the use, safety measures, and maintenance.
  2. Do not put the installation into operation or prevent the operation of pressure equipment if the requirements of the regulations are not met.
  3. It is necessary to have, at least, the following documentation of the pressure equipment while they are installed: Declaration of Conformity, if applicable, manufacturer’s instructions, and, if necessary, installation certificate, along with other supporting documentation (such as Installation Project, record of the last periodic inspection, certifications of equipment repairs or modifications, as well as any other documentation required by the corresponding complementary technical instruction (ITC) of this regulation). For detailed information, please refer to Annex IV of the regulation. This documentation should be made available to the competent authority of the autonomous community and to the companies that carry out maintenance, repairs, or periodic inspections.
  4. Use the pressure equipment within the intended operating limits specified by the manufacturer, and remove them from service if they no longer meet the necessary safety requirements.
  5. Perform maintenance on the installations, pressure equipment, safety accessories, and control devices in accordance with the operating conditions and manufacturer’s instructions, and conduct inspections at least once a year.
  6. Arrange for the necessary periodic inspections as stipulated in Article 6 of the regulation.
  7. Maintain an up-to-date record of pressure equipment belonging to categories I to IV, as defined in RD 709/2015, dated July 24th, or equipment deemed equivalent to these categories according to Article 3.2 of the regulation, as well as their installations.

It is known that by applying heat to water, it transforms into steam at its boiling point under atmospheric pressure. From this point onwards, depending on the desired level of steam saturation for its proper application, we may need to increase the pressure in order to achieve higher temperature. To change the temperature and saturation level of the steam, we always need to adjust the pressure.

It is a unit of pressure equivalent to 1 kg/cm2, 0.98 atmospheres, or 14.50 PSI.

Couldn't find answers to your questions?

Please send us a question or download all the information

    This can be an H2 headline.

    Other similar Success Stories.

    Isotank Cleaning LINE. Giconmes industrial steam generators
    Fuel heating Synhelion. Giconmes industrial steam generators

    Steam flow control line

    Flecha
    Industrial Steam for Assembly UOMJ8165. Giconmes industrial steam generators

    Line Steam Installation for Shoe Production

    Flecha