{"id":7237,"date":"2024-03-22T11:28:42","date_gmt":"2024-03-22T10:28:42","guid":{"rendered":"https:\/\/giconmes.es\/generadores-vapor\/static-steam-generators\/hgv-range-and-hgv-w\/"},"modified":"2024-05-10T10:29:32","modified_gmt":"2024-05-10T10:29:32","slug":"hgv-range-and-hgv-w","status":"publish","type":"productos","link":"https:\/\/giconmes.es\/en\/steam-generators\/static-steam-generators\/hgv-range-and-hgv-w\/","title":{"rendered":"HGV range  <br>and HGV-W"},"content":{"rendered":"\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-1 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"812\" height=\"804\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/04\/23-0081-00-3-e1712316605869-edited-1.jpg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6872\" title=\"Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/04\/23-0081-00-3-e1712316605869-edited-1.jpg 812w, https:\/\/giconmes.es\/wp-content\/uploads\/2024\/04\/23-0081-00-3-e1712316605869-edited-1-300x297.jpg 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2024\/04\/23-0081-00-3-e1712316605869-edited-1-150x150.jpg 150w, https:\/\/giconmes.es\/wp-content\/uploads\/2024\/04\/23-0081-00-3-e1712316605869-edited-1-768x760.jpg 768w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading text-h5 has-primary-90-color has-text-color has-large-font-size\">HGV range<\/h2>\n\n\n\n<h3 class=\"wp-block-heading text-h5 has-primary-90-color has-text-color has-medium-font-size\">Steam Boilers<\/h3>\n\n\n\n<p>Converting electrical energy into heat is becoming increasingly common. Thanks to the increase in renewable energy installations, there are times of the day when surplus electricity is produced at a very low cost. This surplus can be converted into thermal energy with so-called <strong>&#8220;PowertoHeat&#8221;<\/strong> systems.<\/p>\n\n\n\n<p>The HGV range of boilers specially manufactured for heat transfer can produce up to 10,000kg\/hour of steam at 16 bar.<\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-398\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/settings-2.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Plug and play: mounted on SKIDS for easy on-site installation<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-400\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/link-2.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Electric operation does not require gas\/oil supply or chimney system<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-399\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/layout-list.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Up to 10MW and 15 bar<br\/>Low and medium voltage<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-402\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/sliders.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Control panel with system visualization, various interfaces to existing building management systems (BMS)<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-403\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/timer.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Design and manufacture according to PED 2014\/68\/EC or ASME Sect. VIII Div. 1<\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-secondary-background-color has-background wp-element-button\" href=\"https:\/\/giconmes.es\/en\/contact-us\/\">Can we assist you?<\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline is-style-outline--1\"><a class=\"wp-block-button__link has-primary-color has-text-color wp-element-button\" href=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/ficha_tecnica_HGV.pdf\">Download datasheet<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-group alignfull has-body-white-background-color has-background\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-2 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:15%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center text-h2\"><span class=\"has-primary-color has-text-color\">Elements included in a high-capacity clean steam system<\/span><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:15%\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-3 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-1.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2900\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Clean steam generator<\/strong><\/p>\n\n\n\n<p>Clean steam boiler made of high quality stainless steel AISI 316.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-2.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2898\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Purge system<\/strong><\/p>\n\n\n\n<p>Washing of the bottom of the boiler where sediments accumulate.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-3.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2896\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Level control<\/strong><\/p>\n\n\n\n<p>Through water conductivity. If the value is too high, the valve opens until the measured value drops below the set point.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-4.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2894\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Pressure control<\/strong><\/p>\n\n\n\n<p>The pressure will be adjusted mechanically (by means of a mechanical pressure control valve) or electrically by means of a pressure transmitter (control panel) and an electrically operated valve.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-4 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-5.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2892\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Steam supply<\/strong><\/p>\n\n\n\n<p>Clean steam output from the steam generator.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-6.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2890\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>500 liter fermenter<\/strong><\/p>\n\n\n\n<p>Accumulation of boiler feed water. It also serves as a condensate collector. Includes water preheating system<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-7.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2888\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>System for draining excess water in the reservoir<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/07\/Number-8.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-2886\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Heating flange for electric heating elements<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_9.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6754\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Cooling system<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number-10-1.svg\" alt=\". Giconmes industrial steam generators\" style=\"object-fit:cover\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong><strong>Level<\/strong><strong>control <\/strong><\/strong><\/p>\n\n\n\n<p>A water level control system is required. Low and high water protection is installed.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;6a0c14964e39e&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter size-full wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"756\" height=\"396\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on-async--click=\"actions.showLightbox\" data-wp-on-async--load=\"callbacks.setButtonStyles\" data-wp-on-async-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/esquema_sistemas_de_vapor_limpio_de_alta_capacidad.jpg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6703\" title=\"Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/esquema_sistemas_de_vapor_limpio_de_alta_capacidad.jpg 756w, https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/esquema_sistemas_de_vapor_limpio_de_alta_capacidad-300x157.jpg 300w\" sizes=\"auto, (max-width: 756px) 100vw, 756px\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on-async--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"state.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-5 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_11.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6758\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong><strong>Water preheating<\/strong><\/strong><\/p>\n\n\n\n<p>To protect the boiler against large temperature differences and thermal stresses, the feed water must be preheated by steam injection.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_12.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6760\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong><strong>Drainage<\/strong><\/strong><\/p>\n\n\n\n<p>To empty the tank.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_13.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6762\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Water supply connection<\/strong><\/p>\n\n\n\n<p>To feed water pumps and boilers.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_14.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6764\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong><strong><strong>Return condensing<\/strong><\/strong><\/strong><\/p>\n\n\n\n<p>It collects condensate from different elements, e.g. steam pipe drain points or heat exchangers.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-6 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_15.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6766\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong>Blow cooler<\/strong><\/p>\n\n\n\n<p>To cool the hot water of the purges.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_16.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6768\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong><strong><strong>Water sample cooler  <\/strong><\/strong><\/strong><\/p>\n\n\n\n<p>For daily analysis of boiler water.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_17.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6770\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong><strong><strong>Feed water pump unit  <\/strong><\/strong><\/strong><\/p>\n\n\n\n<p>Vertical multistage centrifugal feedwater pump feeding the steam generator. The pump is designed according to the maximum steam pressure and flow capacity of the steam boiler.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"32\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/Number_18.svg\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6772\" title=\"Giconmes industrial steam generators\"><\/figure>\n\n\n\n<p><strong><strong><strong><strong>Main control panel<\/strong><\/strong><\/strong><\/strong><\/p>\n\n\n\n<p>With independent regulation of steam generation and control of safety devices.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<h2 class=\"wp-block-heading\">HGV range<\/h2>\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-primary-20-background-color has-background\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Model No.<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Capacity  <\/strong><br\/><strong>kg\/h<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong><strong>Power rating<\/strong><\/strong><br\/><strong><strong>kW @ 10bar<\/strong><\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Operating pressure  <\/strong><br\/><strong>bar(g)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Approximate dimensions<br\/>  (in mm)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Mains voltage \/ Frequency<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-250<\/td><td class=\"has-text-align-center\" data-align=\"center\">250<\/td><td class=\"has-text-align-center\" data-align=\"center\">140<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">3200 x 1500 x 2000<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-500<\/td><td class=\"has-text-align-center\" data-align=\"center\">500<\/td><td class=\"has-text-align-center\" data-align=\"center\">280<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">3750 x 1500x 2300<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-750<\/td><td class=\"has-text-align-center\" data-align=\"center\">750<\/td><td class=\"has-text-align-center\" data-align=\"center\">420<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">4200 x 1500 x 2500<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">560<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">4500 x 1500 x 2600<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-1500<\/td><td class=\"has-text-align-center\" data-align=\"center\">1500<\/td><td class=\"has-text-align-center\" data-align=\"center\">835<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">5000 x 1750 x 3200<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-2000<\/td><td class=\"has-text-align-center\" data-align=\"center\">2000<\/td><td class=\"has-text-align-center\" data-align=\"center\">1120<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">5500 x 1750 x 3500<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-2500<\/td><td class=\"has-text-align-center\" data-align=\"center\">2500<\/td><td class=\"has-text-align-center\" data-align=\"center\">1395<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">6000 x 2000 x 3800<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-3000<\/td><td class=\"has-text-align-center\" data-align=\"center\">3000<\/td><td class=\"has-text-align-center\" data-align=\"center\">1670<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">on request<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-4000<\/td><td class=\"has-text-align-center\" data-align=\"center\">4000<\/td><td class=\"has-text-align-center\" data-align=\"center\">2240<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">on request<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-5000<\/td><td class=\"has-text-align-center\" data-align=\"center\">5000<\/td><td class=\"has-text-align-center\" data-align=\"center\">2790<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">on request<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-6000<\/td><td class=\"has-text-align-center\" data-align=\"center\">6000<\/td><td class=\"has-text-align-center\" data-align=\"center\">3340<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">on request<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-7500<\/td><td class=\"has-text-align-center\" data-align=\"center\">7500<\/td><td class=\"has-text-align-center\" data-align=\"center\">4480<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">on request<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV-10000<\/td><td class=\"has-text-align-center\" data-align=\"center\">10000<\/td><td class=\"has-text-align-center\" data-align=\"center\">5580<\/td><td class=\"has-text-align-center\" data-align=\"center\">6\/10\/16<\/td><td class=\"has-text-align-center\" data-align=\"center\">on request<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 690V &#8211; 50Hz\/60Hz<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/agua_caliente.png\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-6583\" title=\"Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/agua_caliente.png 500w, https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/agua_caliente-300x300.png 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/agua_caliente-150x150.png 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading text-h5 has-primary-90-color has-text-color has-large-font-size\">HGV &#8211; W Range<\/h2>\n\n\n\n<h3 class=\"wp-block-heading text-h5 has-primary-90-color has-text-color has-medium-font-size\">Hot Water<\/h3>\n\n\n\n<p>Hot water generation by means of electric heating elements. The desired hot water temperature is controlled by a microprocessor.<\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-398\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/settings-2.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Hot water generation by means of electric heating elements. The desired hot water temperature is controlled by a microprocessor.<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-400\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/link-2.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Manufactured with electrical resistors<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-399\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/layout-list.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Up to 30MW<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-402\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/sliders.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Digital control panel with display that integrates into building management systems (BMS)<\/p>\n\n\n\n<p class=\"is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-403\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/timer.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">Suitable for heating, district heating and domestic hot water production<\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-secondary-background-color has-background wp-element-button\" href=\"https:\/\/giconmes.es\/en\/contact-us\/\">Can we assist you?<\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline is-style-outline--2\"><a class=\"wp-block-button__link has-primary-color has-text-color wp-element-button\" href=\"https:\/\/giconmes.es\/wp-content\/uploads\/2024\/03\/ficha_tecnica_HGV-W.pdf\">Download datasheet<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<h2 class=\"wp-block-heading\">HGV &#8211; W Range<\/h2>\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-primary-20-background-color has-background\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Model No.<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Capacity  <\/strong><br\/><strong>liters<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Power rating<\/strong><br\/><strong>  kW<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Water flow rate  <br\/>(m3\/h) Delta T = 20 K<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Approximate dimensions<br\/>  (in mm)<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Mains voltage \/ Frequency<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-75<\/td><td class=\"has-text-align-center\" data-align=\"center\">215<\/td><td class=\"has-text-align-center\" data-align=\"center\">72<\/td><td class=\"has-text-align-center\" data-align=\"center\">3,09<\/td><td class=\"has-text-align-center\" data-align=\"center\">1400 x 1000 x 1800<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-100<\/td><td class=\"has-text-align-center\" data-align=\"center\">350<\/td><td class=\"has-text-align-center\" data-align=\"center\">108<\/td><td class=\"has-text-align-center\" data-align=\"center\">4,64<\/td><td class=\"has-text-align-center\" data-align=\"center\">1400 x 1000 x 1800<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-160<\/td><td class=\"has-text-align-center\" data-align=\"center\">500<\/td><td class=\"has-text-align-center\" data-align=\"center\">162<\/td><td class=\"has-text-align-center\" data-align=\"center\">6,965<\/td><td class=\"has-text-align-center\" data-align=\"center\">1400 x 1000 x 1800<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-250<\/td><td class=\"has-text-align-center\" data-align=\"center\">800<\/td><td class=\"has-text-align-center\" data-align=\"center\">252<\/td><td class=\"has-text-align-center\" data-align=\"center\">10,83<\/td><td class=\"has-text-align-center\" data-align=\"center\">1750 x 1100 x 2200<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-300<\/td><td class=\"has-text-align-center\" data-align=\"center\">800<\/td><td class=\"has-text-align-center\" data-align=\"center\">306<\/td><td class=\"has-text-align-center\" data-align=\"center\">13,16<\/td><td class=\"has-text-align-center\" data-align=\"center\">1790 x 1100 x 2000<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-400<\/td><td class=\"has-text-align-center\" data-align=\"center\">1250<\/td><td class=\"has-text-align-center\" data-align=\"center\">396<\/td><td class=\"has-text-align-center\" data-align=\"center\">17,03<\/td><td class=\"has-text-align-center\" data-align=\"center\">1900 x 1300 x 2200<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-500<\/td><td class=\"has-text-align-center\" data-align=\"center\">1250<\/td><td class=\"has-text-align-center\" data-align=\"center\">504<\/td><td class=\"has-text-align-center\" data-align=\"center\">21,67<\/td><td class=\"has-text-align-center\" data-align=\"center\">2820 x 1700 x 2250<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-660<\/td><td class=\"has-text-align-center\" data-align=\"center\">1250<\/td><td class=\"has-text-align-center\" data-align=\"center\">666<\/td><td class=\"has-text-align-center\" data-align=\"center\">28,63<\/td><td class=\"has-text-align-center\" data-align=\"center\">2820 x 1700 x 2250<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-800<\/td><td class=\"has-text-align-center\" data-align=\"center\">1250<\/td><td class=\"has-text-align-center\" data-align=\"center\">792<\/td><td class=\"has-text-align-center\" data-align=\"center\">34,05<\/td><td class=\"has-text-align-center\" data-align=\"center\">2820 x 1700 x 2250<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">2500<\/td><td class=\"has-text-align-center\" data-align=\"center\">1008<\/td><td class=\"has-text-align-center\" data-align=\"center\">42,99<\/td><td class=\"has-text-align-center\" data-align=\"center\">2820 x 2350 x 2200<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-1200<\/td><td class=\"has-text-align-center\" data-align=\"center\">3000<\/td><td class=\"has-text-align-center\" data-align=\"center\">1188<\/td><td class=\"has-text-align-center\" data-align=\"center\">51,07<\/td><td class=\"has-text-align-center\" data-align=\"center\">2820 x 2350 x 2350<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-1500<\/td><td class=\"has-text-align-center\" data-align=\"center\">3500<\/td><td class=\"has-text-align-center\" data-align=\"center\">1512<\/td><td class=\"has-text-align-center\" data-align=\"center\">65,00<\/td><td class=\"has-text-align-center\" data-align=\"center\">2820 x 2450 x 2450<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">HGV W-2000<\/td><td class=\"has-text-align-center\" data-align=\"center\">4400<\/td><td class=\"has-text-align-center\" data-align=\"center\">2016<\/td><td class=\"has-text-align-center\" data-align=\"center\">85,98<\/td><td class=\"has-text-align-center\" data-align=\"center\">4000 x 2500 x 2500<\/td><td class=\"has-text-align-center\" data-align=\"center\">3 PH 400V\/690V &#8211; 50Hz\/60Hz<\/td><\/tr><\/tbody><\/table><\/figure>\n\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-group alignfull has-bg-20-background-color has-background\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading text-h5 has-primary-90-color has-text-color\">Why choose an electric steam generator?<\/h2>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"is-style-arrow-list\">\n<li><strong>Efficiency:<\/strong> Even at low utilization levels, the electric alternative is more efficient than fossil fuels, allowing to reduce the installation size for the same generation capacity.<\/li>\n\n\n\n<li><strong>Zero emissions of pollutants:<\/strong> It has neutral direct emissions and the potential to be 100% clean through the use of renewable energy.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"is-style-arrow-list\">\n<li><strong>Safety:<\/strong> There is no combustion, smoke, or other gas emissions. It also does not require a specialist to operate or a boiler room.<\/li>\n\n\n\n<li><strong>Maintenance cost:<\/strong>Due to their simpler structural and mechanical design, electric steam generators streamline and reduce maintenance time and costs.<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"is-style-arrow-list\">\n<li><strong>Incremental power based on <br\/> needs (modularity):<\/strong> The possibility to configure a generator modularly with multiple independent power options.<\/li>\n\n\n\n<li><strong>Simplified installation:<\/strong>Electric boilers can be installed near the point of<br\/>steam application, reducing installation costs and inefficiencies in pressure and temperature.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-11 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading text-h4\">Steam generator accessories<\/h2>\n\n\n\n<p><strong>Custom-designed accessories for each customer<\/strong><br\/>Optimize operating costs, steam quality, and find solutions to your needs by incorporating the available accessories to your generator. We will be delighted to assist you in selecting the right ones for your requirements!<\/p>\n\n\n\n<div style=\"height:72px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-container--grid-pages\">\n\t<div class=\"grid-columns-1\">\n\t\t<div id=\"post-2614\" class=\"card-horizontal post-2614 productos type-productos status-publish has-post-thumbnail hentry\">  \n    <div class=\"card-img\">\n        <img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"160\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Accesorios-limpieza-II-200x160.png\" class=\"attachment-card-horizontal size-card-horizontal wp-post-image\" alt=\". Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Accesorios-limpieza-II-200x160.png 200w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Accesorios-limpieza-II-300x238.png 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Accesorios-limpieza-II-1024x812.png 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Accesorios-limpieza-II-768x609.png 768w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Accesorios-limpieza-II-1536x1219.png 1536w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Accesorios-limpieza-II.png 1917w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" title=\"Giconmes industrial steam generators\">    <\/div>\n    \n    <div class=\"card-title\">  \n              \n        <h2 class=\"text-h5\"><a href=\"https:\/\/giconmes.es\/en\/steam-generators\/accesories\/cleaning-accessories\/\" title=\"Cleaning Accessories\">Cleaning Accessories<\/a><\/h2>\n        <div class=\"card-icon\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/giconmes.es\/wp-content\/themes\/giconmes\/assets\/icons\/arrow-card.svg\" width=\"44\" height=\"32\" alt=\"Flecha\" title=\"Giconmes industrial steam generators\"><\/div>\n    <\/div> \n<\/div><div id=\"post-2615\" class=\"card-horizontal post-2615 productos type-productos status-publish has-post-thumbnail hentry\">  \n    <div class=\"card-img\">\n        <img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"160\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/Calentador-Agua-Vapor-200x160.png\" class=\"attachment-card-horizontal size-card-horizontal wp-post-image\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">    <\/div>\n    \n    <div class=\"card-title\">  \n              \n        <h2 class=\"text-h5\"><a href=\"https:\/\/giconmes.es\/en\/steam-generators\/accesories\/hot-water\/\" title=\"Hot water\">Hot water<\/a><\/h2>\n        <div class=\"card-icon\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/giconmes.es\/wp-content\/themes\/giconmes\/assets\/icons\/arrow-card.svg\" width=\"44\" height=\"32\" alt=\"Flecha\" title=\"Giconmes industrial steam generators\"><\/div>\n    <\/div> \n<\/div><div id=\"post-2623\" class=\"card-horizontal post-2623 productos type-productos status-publish has-post-thumbnail hentry\">  \n    <div class=\"card-img\">\n        <img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"160\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/sobrecalentador-200x160.png\" class=\"attachment-card-horizontal size-card-horizontal wp-post-image\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">    <\/div>\n    \n    <div class=\"card-title\">  \n              \n        <h2 class=\"text-h5\"><a href=\"https:\/\/giconmes.es\/en\/steam-generators\/accesories\/overheater\/\" title=\"Overheater\">Overheater<\/a><\/h2>\n        <div class=\"card-icon\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/giconmes.es\/wp-content\/themes\/giconmes\/assets\/icons\/arrow-card.svg\" width=\"44\" height=\"32\" alt=\"Flecha\" title=\"Giconmes industrial steam generators\"><\/div>\n    <\/div> \n<\/div><div id=\"post-2624\" class=\"card-horizontal post-2624 productos type-productos status-publish has-post-thumbnail hentry\">  \n    <div class=\"card-img\">\n        <img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"160\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/PLC-200x160.png\" class=\"attachment-card-horizontal size-card-horizontal wp-post-image\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">    <\/div>\n    \n    <div class=\"card-title\">  \n              \n        <h2 class=\"text-h5\"><a href=\"https:\/\/giconmes.es\/en\/steam-generators\/accesories\/control-systems\/\" title=\"Control systems\">Control systems<\/a><\/h2>\n        <div class=\"card-icon\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/giconmes.es\/wp-content\/themes\/giconmes\/assets\/icons\/arrow-card.svg\" width=\"44\" height=\"32\" alt=\"Flecha\" title=\"Giconmes industrial steam generators\"><\/div>\n    <\/div> \n<\/div>    <\/div>\n<\/div>\n\n\n\n\n<div style=\"height:72px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading text-h4\">Industries and applications for the HGV and HGV-W Range<\/h2>\n\n\n\n<p><strong>Steam is used in heating, sterilization, or sanitation processes <\/strong><br\/>The engineers at Giconmes have been developing numerous applications based on heat transfer through steam since 1957. You can find examples of our solutions in the following case studies<\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"card-block\">\n            \n            <div class=\"card-img\">\n                <img loading=\"lazy\" decoding=\"async\" width=\"1600\" height=\"1200\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/UOMJ8165.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\". Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/UOMJ8165.jpg 1600w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/UOMJ8165-300x225.jpg 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/UOMJ8165-1024x768.jpg 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/UOMJ8165-768x576.jpg 768w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/UOMJ8165-1536x1152.jpg 1536w\" sizes=\"auto, (max-width: 1600px) 100vw, 1600px\" title=\"Giconmes industrial steam generators\">            <\/div>\n            \n            <div class=\"card-title\">\n                <h2 class=\"text-h4\"><a href=\"https:\/\/giconmes.es\/en\/success-stories\/industrial-steam-for-assembly\/\">Industrial Steam for Assembly<\/a><\/h2>\n            <\/div>\n    \n            <div class=\"card-exceprt\">\n                <p>Line Steam Installation for Shoe Production<\/p>\n            <\/div>\n    \n            <div class=\"card-icon\">\n                <img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/giconmes.es\/wp-content\/themes\/giconmes\/assets\/icons\/arrow-card.svg\" width=\"56\" height=\"40\" alt=\"Flecha\" title=\"Giconmes industrial steam generators\">\n            <\/div>\t\n            \n        <\/div>\n    \n\n\n\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-10 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:8.33%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<ul class=\"is-style-arrow-list text-h5 has-body-medium-color has-text-color\">\n<li><a href=\"https:\/\/giconmes.es\/en\/industrias\/bakery-and-pastry\/\" data-type=\"industries\" data-id=\"154\">Bakery and Pastry Shop<\/a><strong> <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-556\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/croissant.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\"><\/li>\n\n\n\n<li><a href=\"https:\/\/giconmes.es\/en\/industrias\/pharmacy-and-healthcare\/\" data-type=\"industries\" data-id=\"159\">Pharmacy and Healthcare<\/a>  <strong> <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"26\" height=\"26\" class=\"wp-image-557\" style=\"width: 26px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/cross.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\"><\/li>\n\n\n\n<li><a href=\"https:\/\/giconmes.es\/en\/industrias\/brewing-sector\/\" data-type=\"industries\" data-id=\"153\">Beer Industry<\/a><strong><img loading=\"lazy\" decoding=\"async\" width=\"24\" height=\"24\" class=\"wp-image-552\" style=\"width: 24px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/beer.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\"><\/strong><\/li>\n\n\n\n<li><a href=\"https:\/\/giconmes.es\/en\/industrias\/biotechnology\/\" data-type=\"industries\" data-id=\"158\">Biotechnology<\/a><strong> <\/strong><img loading=\"lazy\" decoding=\"async\" width=\"26\" height=\"26\" class=\"wp-image-558\" style=\"width: 26px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/vector.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\"><\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns are-vertically-aligned-center mb-0 has-body-white-color has-primary-background-color has-text-color has-background is-layout-flex wp-container-core-columns-is-layout-12 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:8.33%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"text-h4 is-style-title-has-image\"><img loading=\"lazy\" decoding=\"async\" width=\"33\" height=\"24\" class=\"wp-image-447\" style=\"width: 33px;\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/dot.svg\" alt=\". Giconmes industrial steam generators\" title=\"Giconmes industrial steam generators\">FAQs<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"text-h5\">We understand that many questions may arise. Here are some of the most common ones.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:8.33%\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-bg-40-background-color has-background is-layout-flex wp-container-core-columns-is-layout-14 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:8.33%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n\n<div id=\"faqs--block_0da2fddf030de4d2affc0fe0f8892def\" class=\"faqs-block mb-6\">\n        \n    <button class=\"faqs-btn\">\n        <span>\n            <div class=\"screen-reader-text\">Open<\/div>\n        <\/span>\n        What kind of emissions does an electric boiler produce?    <\/button>\n\n    <div class=\"faqs-content\">\n        <div class=\"mt-1 mb-2\"><p class=\"p1\">There are no emissions beyond those produced during the electricity production process. Consequently, emissions can be neutral depending on the electricity mix. Electric steam boilers are the present and the future.<\/p>\n<\/div>\n    <\/div>\n\n        \n    <button class=\"faqs-btn\">\n        <span>\n            <div class=\"screen-reader-text\">Open<\/div>\n        <\/span>\n        Is it possible to automate the operation of a steam generator? Can it be remotely controlled?    <\/button>\n\n    <div class=\"faqs-content\">\n        <div class=\"mt-1 mb-2\"><p class=\"p1\">Absolutely. In fact, it is recommended to achieve maximum efficiency. There is no problem with remote control as long as it complies with current regulations.<\/p>\n<\/div>\n    <\/div>\n\n        \n    <button class=\"faqs-btn\">\n        <span>\n            <div class=\"screen-reader-text\">Open<\/div>\n        <\/span>\n        What maintenance does an electric steam generator require?    <\/button>\n\n    <div class=\"faqs-content\">\n        <div class=\"mt-1 mb-2\"><p class=\"p1\">A steam generator is a pressure vessel that, together with the piping network, is subject to regulatory control and complementary technical instructions, according to the regulations published in Royal Decree 809\/2021, of September 21. Maintenance is divided into a part that can be easily fulfilled by the owner:<\/p>\n<ol>\n<li class=\"p1\">Know and apply the manufacturer&#8217;s instructions regarding use, safety measures, and maintenance.<\/li>\n<li class=\"p1\">Not to put the installation into service or prevent the operation of pressure equipment if the requirements of the Regulation are not met.<\/li>\n<li class=\"p1\">Having at least the following documentation for the pressure equipment while they are installed: Declaration of conformity, manufacturer&#8217;s instructions (if applicable), and, if necessary, installation certificate, along with other supporting documentation (such as installation project, record of the last periodic inspection, certifications of equipment repairs or modifications, and any other documentation required by the relevant technical instruction complementary to this regulation). For detailed contents, refer to Annex IV of the regulation. Making this documentation available to the competent authority of the autonomous community and the companies responsible for maintenance, repair, or periodic inspections.<\/li>\n<li class=\"p1\">Use the pressure equipment within its intended operating limits as specified by the manufacturer and take it out of service if it no longer meets the necessary safety requirements.<\/li>\n<li class=\"p1\">Perform maintenance on the installations, pressure equipment, safety accessories, and control devices in accordance with the operating conditions and manufacturer&#8217;s instructions, and <b>examine them at least once a year. <\/b> <\/li>\n<li class=\"p1\">Arranging for the necessary periodic inspections as required by Article 6 of the regulation.<\/li>\n<li class=\"p1\">Having and maintaining an up-to-date record of pressure equipment categories I to IV, as defined in RD 709\/2015, of July 24, or equipment similar to these categories according to Article 3.2 of the regulation, as well as their installations.<\/li>\n<\/ol>\n<\/div>\n    <\/div>\n\n        \n    <button class=\"faqs-btn\">\n        <span>\n            <div class=\"screen-reader-text\">Open<\/div>\n        <\/span>\n        At what temperature is steam produced? Can it be controlled and adjusted according to needs?    <\/button>\n\n    <div class=\"faqs-content\">\n        <div class=\"mt-1 mb-2\"><p class=\"p1\">It is known that by applying heat to water, it transforms into steam at the boiling point and atmospheric pressure. From there, depending on the required saturation degree of steam for its proper application, we need to increase the pressure to obtain a higher temperature. To change the temperature and saturation degree of steam, we always need to modify the pressure.<\/p>\n<\/div>\n    <\/div>\n\n        \n    <button class=\"faqs-btn\">\n        <span>\n            <div class=\"screen-reader-text\">Open<\/div>\n        <\/span>\n        What is a &#8220;bar&#8221; in thermodynamics?    <\/button>\n\n    <div class=\"faqs-content\">\n        <div class=\"mt-1 mb-2\"><p class=\"p1\">It is a unit of pressure equivalent to 1 kg\/cm2, 0.98 atmospheres, or 14.50 PSI.<\/p>\n<\/div>\n    <\/div>\n\n    <\/div>\n\n<script>\nvar acc = document.querySelectorAll( \"#faqs--block_0da2fddf030de4d2affc0fe0f8892def .faqs-btn\");\nvar i;\n\nfor (i = 0; i < acc.length; i++) {\n    acc[i].addEventListener(\"click\", function() {\n        this.classList.toggle(\"active\");\n        var panel = this.nextElementSibling;\n        if (panel.style.maxHeight) {\n            panel.style.maxHeight = null;\n        } else {\n            panel.style.maxHeight = panel.scrollHeight + \"px\";\n        }\n    });\n}\n<\/script>\n\n\n<div style=\"height:56px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-13 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"text-h3 has-body-medium-color has-text-color\">Haven't found the answers to your questions?<\/p>\n\n\n\n<p>Please send us a question or download all the information<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-contact-form-7-contact-form-selector\">\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f3111-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"3111\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/productos\/7237#wpcf7-f3111-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"3111\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.6\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f3111-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/><input type=\"hidden\" name=\"_wpcf7_recaptcha_response\" value=\"\" \/>\n<\/fieldset>\n<p><label> Name<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" autocomplete=\"name\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span> <\/label>\n<\/p>\n<p><label> Email<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" autocomplete=\"email\" aria-required=\"true\" aria-invalid=\"false\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span> <\/label>\n<\/p>\n<p><label> Message (optional)<br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"4\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" name=\"your-message\"><\/textarea><\/span> <\/label>\n<\/p>\n<p><span class=\"wpcf7-form-control-wrap\" data-name=\"acceptance-320\"><span class=\"wpcf7-form-control wpcf7-acceptance\"><span class=\"wpcf7-list-item\"><label><input type=\"checkbox\" name=\"acceptance-320\" value=\"1\" aria-invalid=\"false\" \/><span class=\"wpcf7-list-item-label\">I have read and accept the <a href=\"\">privacy policy<\/a><\/span><\/label><\/span><\/span><\/span>\n<\/p>\n<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"Send\" \/>\n<\/p><p style=\"display: none !important;\" class=\"akismet-fields-container\" data-prefix=\"_wpcf7_ak_\"><label>&#916;<textarea name=\"_wpcf7_ak_hp_textarea\" cols=\"45\" rows=\"8\" maxlength=\"100\"><\/textarea><\/label><input type=\"hidden\" id=\"ak_js_1\" name=\"_wpcf7_ak_js\" value=\"120\"\/><script>\ndocument.getElementById( \"ak_js_1\" ).setAttribute( \"value\", ( new Date() ).getTime() );\n<\/script>\n<\/p><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:8.33%\"><\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-cover alignwide\" style=\"min-height:784px;aspect-ratio:unset;\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-primary-100-background-color has-background-dim\"><\/span><img loading=\"lazy\" decoding=\"async\" width=\"1312\" height=\"844\" class=\"wp-block-cover__image-background wp-image-357\" alt=\". Giconmes industrial steam generators\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/CTA-2.jpg\" data-object-fit=\"cover\" title=\"Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/CTA-2.jpg 1312w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/CTA-2-300x193.jpg 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/CTA-2-1024x659.jpg 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/CTA-2-768x494.jpg 768w\" sizes=\"auto, (max-width: 1312px) 100vw, 1312px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div style=\"height:124px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-15 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<p class=\"has-text-align-left text-h3 has-body-white-color has-text-color has-large-font-size\">Quick technical service, with trained professionals and service plans focused on your company<\/p>\n\n\n\n<div style=\"height:56px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-primary-background-color has-background wp-element-button\" href=\"Tel: +34976500108\">CALL US<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-secondary-background-color has-background wp-element-button\" href=\"https:\/\/giconmes.es\/en\/contact-us\/\">CONTACT US<\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline is-style-outline--3\"><a class=\"wp-block-button__link has-body-white-color has-text-color wp-element-button\" href=\"https:\/\/giconmes.es\/en\/engineering\/faqs\/\">FAQs<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:124px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group alignfull has-gradient-left-gradient-background has-background\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-16 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"text-h6\">What kind of steam system do you need?<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Equipment rental<\/h2>\n\n\n\n<p class=\"text-h4 has-primary-color has-text-color\">Reliable, safe equipment with a 5-year warranty.<\/p>\n\n\n\n<div style=\"height:32px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Enjoy the security of a personalized service<br\/>24\/7 adapted to your needs.<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><a href=\"https:\/\/giconmes.es\/en\/generator-rental\/\" data-type=\"page\" data-id=\"21\"><strong>EQUIPMENT RENTAL<\/strong><\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:8.3%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"518\" height=\"810\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/alquiler-maquinaria.png\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-422\" title=\"Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/alquiler-maquinaria.png 518w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/alquiler-maquinaria-192x300.png 192w\" sizes=\"auto, (max-width: 518px) 100vw, 518px\" \/><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<div class=\"wp-block-cover is-light\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-primary-100-background-color has-background-dim\"><\/span><img loading=\"lazy\" decoding=\"async\" width=\"1216\" height=\"464\" class=\"wp-block-cover__image-background wp-image-459\" alt=\". Giconmes industrial steam generators\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/CTA-3.jpg\" data-object-fit=\"cover\" title=\"Giconmes industrial steam generators\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/CTA-3.jpg 1216w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/CTA-3-300x114.jpg 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/CTA-3-1024x391.jpg 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2023\/01\/CTA-3-768x293.jpg 768w\" sizes=\"auto, (max-width: 1216px) 100vw, 1216px\" \/><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-17 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:16.7%\"><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-text-align-center text-h3 has-body-white-color has-text-color has-large-font-size\">Do you need a customized solution?<\/p>\n\n\n\n<p class=\"has-text-align-center text-h5 has-body-white-color has-text-color\">We help you define what type of installation you need<\/p>\n\n\n\n<div style=\"height:56px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-4 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-primary-background-color has-background wp-element-button\" href=\"tel:+34976500108\">CALL US<\/a><\/div>\n\n\n\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-secondary-background-color has-background wp-element-button\" href=\"https:\/\/giconmes.es\/contacto\/\">CONTACT US<\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline is-style-outline--4\"><a class=\"wp-block-button__link has-body-white-color has-text-color wp-element-button\" href=\"https:\/\/giconmes.es\/faqs\/\">FAQs<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:16.7%\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:64px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns mb-0 is-layout-flex wp-container-core-columns-is-layout-18 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column dnone-tablet is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:8.3%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"9\" height=\"304\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2023\/02\/LINE-blog.png\" alt=\". Giconmes industrial steam generators\" class=\"wp-image-298\" title=\"Giconmes industrial steam generators\"><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<div style=\"height:96px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"text-h2\">Giconmes technology blog<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58.3%\">\n<div style=\"height:96px\" aria-hidden=\"true\" class=\"wp-block-spacer dnone-mobile\"><\/div>\n\n\n\n<p>Here you will find informative articles about <strong>steam technology, its application in industry, and different types of related equipment<\/strong>, as well as the latest trends, installations we have created and new developments in boilers or steam generators for the entire industry.  <\/p>\n\n\n\n<p><a href=\"https:\/\/giconmes.es\/en\/blog\/\" data-type=\"page\" data-id=\"7\"><strong>GO TO THE BLOG<\/strong><\/a><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-query is-layout-flow wp-block-query-is-layout-flow\"><ul class=\"columns-3 wp-block-post-template is-layout-grid wp-container-core-post-template-is-layout-1 wp-block-post-template-is-layout-grid\"><li class=\"wp-block-post post-20083 post type-post status-publish format-standard has-post-thumbnail hentry category-industry\">\n<figure style=\"height:280px;\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/giconmes.es\/en\/the-no-1-mistake-in-industrial-steam-electrification-and-how-to-avoid-it\/\" target=\"_self\"  style=\"height:280px\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/principal-error-electrificacion-vapor.webp\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"The No. 1 mistake in industrial steam electrification (and how to avoid it)\" style=\"height:280px;object-fit:cover;\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/principal-error-electrificacion-vapor.webp 1536w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/principal-error-electrificacion-vapor-300x200.webp 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/principal-error-electrificacion-vapor-1024x683.webp 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/principal-error-electrificacion-vapor-768x512.webp 768w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" title=\"Giconmes industrial steam generators\"><\/a><\/figure>\n\n<div class=\"wp-block-post-date\"><time datetime=\"2026-04-30T11:00:00+01:00\">30 de April de 2026<\/time><\/div>\n\n<p class=\"wp-block-post-title\"><a href=\"https:\/\/giconmes.es\/en\/the-no-1-mistake-in-industrial-steam-electrification-and-how-to-avoid-it\/\" target=\"_self\" >The No. 1 mistake in industrial steam electrification (and how to avoid it)<\/a><\/h4>\n<\/li><li class=\"wp-block-post post-19935 post type-post status-publish format-standard has-post-thumbnail hentry category-industry category-sin-categorizar\">\n<figure style=\"height:280px;\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/giconmes.es\/en\/electric-steam-boilers-the-proven-technology-that-industry-has-been-ignoring-for-decades\/\" target=\"_self\"  style=\"height:280px\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/calderas-electricas-vapor-industrial-descarbonizacion.webp\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"Electric steam boilers: the proven technology that industry has been ignoring for decades\" style=\"height:280px;object-fit:cover;\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/calderas-electricas-vapor-industrial-descarbonizacion.webp 1536w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/calderas-electricas-vapor-industrial-descarbonizacion-300x200.webp 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/calderas-electricas-vapor-industrial-descarbonizacion-1024x683.webp 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/04\/calderas-electricas-vapor-industrial-descarbonizacion-768x512.webp 768w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" title=\"Giconmes industrial steam generators\"><\/a><\/figure>\n\n<div class=\"wp-block-post-date\"><time datetime=\"2026-04-16T11:00:00+01:00\">16 de April de 2026<\/time><\/div>\n\n<p class=\"wp-block-post-title\"><a href=\"https:\/\/giconmes.es\/en\/electric-steam-boilers-the-proven-technology-that-industry-has-been-ignoring-for-decades\/\" target=\"_self\" >Electric steam boilers: the proven technology that industry has been ignoring for decades<\/a><\/h4>\n<\/li><li class=\"wp-block-post post-19529 post type-post status-publish format-standard has-post-thumbnail hentry category-industry category-sin-categorizar\">\n<figure style=\"height:280px;\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/giconmes.es\/en\/the-role-of-electric-steam-boilers-in-decarbonization-and-industrial-heat-revenues\/\" target=\"_self\"  style=\"height:280px\"><img loading=\"lazy\" decoding=\"async\" width=\"1376\" height=\"729\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/calderas-vapor-electricas-descarbonizacion-ingresos.webp\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"The role of electric steam boilers in decarbonization and industrial heat revenues.\" style=\"height:280px;object-fit:cover;\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/calderas-vapor-electricas-descarbonizacion-ingresos.webp 1376w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/calderas-vapor-electricas-descarbonizacion-ingresos-300x159.webp 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/calderas-vapor-electricas-descarbonizacion-ingresos-1024x543.webp 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/calderas-vapor-electricas-descarbonizacion-ingresos-768x407.webp 768w\" sizes=\"auto, (max-width: 1376px) 100vw, 1376px\" title=\"Giconmes industrial steam generators\"><\/a><\/figure>\n\n<div class=\"wp-block-post-date\"><time datetime=\"2026-03-19T12:00:00+01:00\">19 de March de 2026<\/time><\/div>\n\n<p class=\"wp-block-post-title\"><a href=\"https:\/\/giconmes.es\/en\/the-role-of-electric-steam-boilers-in-decarbonization-and-industrial-heat-revenues\/\" target=\"_self\" >The role of electric steam boilers in decarbonization and industrial heat revenues.<\/a><\/h4>\n<\/li><li class=\"wp-block-post post-19330 post type-post status-publish format-standard has-post-thumbnail hentry category-boilers-and-steam-generators\">\n<figure style=\"height:280px;\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/giconmes.es\/en\/why-many-rooms-do-not-reach-their-intended-temperature-common-mistakes-in-industrial-thermal-sizing\/\" target=\"_self\"  style=\"height:280px\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/dimensionamiento-termico-industrial-errores-comunes.webp\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"Why many rooms do not reach their intended temperature: common mistakes in industrial thermal sizing\" style=\"height:280px;object-fit:cover;\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/dimensionamiento-termico-industrial-errores-comunes.webp 1536w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/dimensionamiento-termico-industrial-errores-comunes-300x200.webp 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/dimensionamiento-termico-industrial-errores-comunes-1024x683.webp 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/03\/dimensionamiento-termico-industrial-errores-comunes-768x512.webp 768w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" title=\"Giconmes industrial steam generators\"><\/a><\/figure>\n\n<div class=\"wp-block-post-date\"><time datetime=\"2026-03-05T11:00:00+01:00\">5 de March de 2026<\/time><\/div>\n\n<p class=\"wp-block-post-title\"><a href=\"https:\/\/giconmes.es\/en\/why-many-rooms-do-not-reach-their-intended-temperature-common-mistakes-in-industrial-thermal-sizing\/\" target=\"_self\" >Why many rooms do not reach their intended temperature: common mistakes in industrial thermal sizing<\/a><\/h4>\n<\/li><li class=\"wp-block-post post-19154 post type-post status-publish format-standard has-post-thumbnail hentry category-sin-categorizar\">\n<figure style=\"height:280px;\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/giconmes.es\/en\/for-heating-reactors-to-70-c-is-an-electric-steam-boiler-or-a-hot-water-boiler-more-efficient\/\" target=\"_self\"  style=\"height:280px\"><img loading=\"lazy\" decoding=\"async\" width=\"1536\" height=\"1024\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/calentar-reactor-70-grados-caldera-de-vapor.webp\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"For heating reactors to 70 \u00b0C, is an electric steam boiler or a hot water boiler more efficient?\" style=\"height:280px;object-fit:cover;\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/calentar-reactor-70-grados-caldera-de-vapor.webp 1536w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/calentar-reactor-70-grados-caldera-de-vapor-300x200.webp 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/calentar-reactor-70-grados-caldera-de-vapor-1024x683.webp 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/calentar-reactor-70-grados-caldera-de-vapor-768x512.webp 768w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" title=\"Giconmes industrial steam generators\"><\/a><\/figure>\n\n<div class=\"wp-block-post-date\"><time datetime=\"2026-02-19T11:00:00+01:00\">19 de February de 2026<\/time><\/div>\n\n<p class=\"wp-block-post-title\"><a href=\"https:\/\/giconmes.es\/en\/for-heating-reactors-to-70-c-is-an-electric-steam-boiler-or-a-hot-water-boiler-more-efficient\/\" target=\"_self\" >For heating reactors to 70 \u00b0C, is an electric steam boiler or a hot water boiler more efficient?<\/a><\/h4>\n<\/li><li class=\"wp-block-post post-19148 post type-post status-publish format-standard has-post-thumbnail hentry category-boilers-and-steam-generators\">\n<figure style=\"height:280px;\" class=\"wp-block-post-featured-image\"><a href=\"https:\/\/giconmes.es\/en\/7-industrial-methods-to-generate-hot-water-with-steam\/\" target=\"_self\"  style=\"height:280px\"><img loading=\"lazy\" decoding=\"async\" width=\"1280\" height=\"853\" src=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/metodos-industriales-generacion-agua-caliente-vapor.webp\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"7 industrial methods to generate hot water with steam\" style=\"height:280px;object-fit:cover;\" srcset=\"https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/metodos-industriales-generacion-agua-caliente-vapor.webp 1280w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/metodos-industriales-generacion-agua-caliente-vapor-300x200.webp 300w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/metodos-industriales-generacion-agua-caliente-vapor-1024x682.webp 1024w, https:\/\/giconmes.es\/wp-content\/uploads\/2026\/02\/metodos-industriales-generacion-agua-caliente-vapor-768x512.webp 768w\" sizes=\"auto, (max-width: 1280px) 100vw, 1280px\" title=\"Giconmes industrial steam generators\"><\/a><\/figure>\n\n<div class=\"wp-block-post-date\"><time datetime=\"2026-02-12T11:00:00+01:00\">12 de February de 2026<\/time><\/div>\n\n<p class=\"wp-block-post-title\"><a href=\"https:\/\/giconmes.es\/en\/7-industrial-methods-to-generate-hot-water-with-steam\/\" target=\"_self\" >7 industrial methods to generate hot water with steam<\/a><\/h4>\n<\/li><\/ul><\/div>\n\n\n\n<div style=\"height:112px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Large capacity steam and hot water boilers (up to 10 MW in steam and 30 MW in hot water). Complete systems including feed tank, purge systems, electrical cabinet and control panel all mounted on a SKID.<\/p>\n","protected":false},"featured_media":6875,"parent":2639,"menu_order":10,"template":"","class_list":["post-7237","productos","type-productos","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/giconmes.es\/en\/wp-json\/wp\/v2\/productos\/7237","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/giconmes.es\/en\/wp-json\/wp\/v2\/productos"}],"about":[{"href":"https:\/\/giconmes.es\/en\/wp-json\/wp\/v2\/types\/productos"}],"up":[{"embeddable":true,"href":"https:\/\/giconmes.es\/en\/wp-json\/wp\/v2\/productos\/2639"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/giconmes.es\/en\/wp-json\/wp\/v2\/media\/6875"}],"wp:attachment":[{"href":"https:\/\/giconmes.es\/en\/wp-json\/wp\/v2\/media?parent=7237"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}